GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

Brief Description:

GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.

 


Product Detail

Product Tags

GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has features of fast measurement, small size, light weight, large output current, perfect protection functions, good repeat-ability, good anti-interference ability, high accuracy, which make it an ideal equipment for measuring DC resistance of transformer winding and high inductive equipment.

Features

Controlled by high-speed single chip microcomputer, highly automatic and easy to operate.
Adopts the new power supply technology with multiple current steps and wide measurement range, which is suitable for DC resistance measurement of large and medium-sized transformers.
Perfect protection functions, able to protect the instrument from the impact of counter EMF, with more reliable performance.
Sound discharge alarm, clear discharge indication, less faulty operation.
Fast response speed, the on-load tap-changer can be directly converted in the measurement state, and the instrument automatically refreshes the data.
Intelligent power management technology. The instrument always works with minimum power, which saves energy and reduces heat effectively.
65K true color LCD of minimum 320X240 super small pixels.
Equipped with a calendar clock and power failure data-store function, which can store 1000 sets of test data and can be reviewed at any time.
Equipped with RS232 (reserved interface) and USB interface (for USB storage).

GDZRC-40U / GDZRC-50U Specifications
Output current <5mA, 2.5A, 5A, 10A, 20A, 40A
Min. resolution 0.1μΩ
Measurement range (GDZRC-50U: 40μΩ~400mΩ)
50μΩ~500mΩ
100μΩ~1Ω
500μΩ~2Ω  
1mΩ~4Ω
2mΩ~8Ω
10Ω~20KΩ
(GDZRC-50U: 50A)
40A
20A
10A
5A
2.5A
<5mA
Accuracy ±(0.2%+2digits)
Operation temperature 0~40℃
Humidity <90%RH (no condensing)
Size  325mm×240mm×275mm (L×W×H) / GDZRC-50U: 400mm×225mm×350mm (L×W×H)
Weight 15kg (without test wire) / GDZRC-50U: 17kg (without test wire) test wire box: 3kg
Accessories
Tester 1 set
Power cord 1 piece
Test wire (red black each one with clamp) 2 pieces
Print paper 2 rolls
Fuse  2 pieces
232 serial wire 1 piece
Shunt 1 piece
Instruction Manual 1 piece
QC pass 1 piece
Packing list 1 piece
Factory test report 1 piece

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us